<ErrorNumber>15373</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Drum vacuum level too low, threshold = &lt;n&gt;, current level = &lt;n&gt; (index word)
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
This error is likely due to the media not being loaded properly.  Select
RESUME from the workstaion dialog box.  If that doesn't correct the problem,
select CANCEL IMAGE from the workstation dialog box.  You may need to open
the proofer and remove the media if it isn't ejected from the proofer on
it's own. IF CANCEL IMAGE is not available, select CLEAR and make sure that
you remove all media other than the carrier in the machine.
If this problem recurs frequently contact Creo service.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
When the problem happens, determine if the media is loaded correctly.
If it is not, then you must watch a few load/unload cycles
with the doors open and try to determine what is going wrong.  If the media
is being loaded correctly, then the vacuum sensors are not working properly,
the vacuum thresholds are mis-adjusted or the vacuum is not being generated
properly.  You can check the vacuum sensor readings using the "proof" command.
Additionally, at the end of the error message, an index word is printed to help
determine which threshold in NVS is being used when error occurs.
</text></DescriptionText>
<DescriptionText><UnnumberedList>
<ListItem><Text>(load_3a) : dvrt</Text></ListItem>
<ListItem><Text>(load_3b) : dvct</Text></ListItem>
<ListItem><Text>(load_6a) : dvrt + ((dvdt - dvrt) / 3)</Text></ListItem>
<ListItem><Text>(load_6b) : dvct + ((dvrt - dvct) / 3)</Text></ListItem>
<ListItem><Text>(load_9a) : dvdt</Text></ListItem>
<ListItem><Text>(load_9b) : dvrt</Text></ListItem>
<ListItem><Text>(load_11a) : dvdt</Text></ListItem>
<ListItem><Text>(load_11b) : dvrt</Text></ListItem>
<ListItem><Text>(load_12a) : dvrt</Text></ListItem>
<ListItem><Text>(load_12b) : dvdt</Text></ListItem>
<ListItem><Text>(unload_0a) : dvdt</Text></ListItem>
<ListItem><Text>(unload_0b) : dvrt</Text></ListItem>
<ListItem><Text>(unload_10a) : dvrt</Text></ListItem>
<ListItem><Text>(unload_10b) : dvct</Text></ListItem>
</UnnumberedList></DescriptionText>
<DescriptionText><text>
Please make sure that the error is NOT due to mechanical alignment before adjusting
NVS thresholds.
</text></DescriptionText>
</ServiceInformation>
<ServiceInformation>
<DescriptionText><text>
The sensors can be over-ridden using the "alproof vsi" parameter.  This
will allow the machine to operate, but in a much slower and more dangerous
manner. In this state, the machine should only be used if absolutely
necessary and if it will be fixed very soon.  When the sensors are disabled,
the machine is running "blind", so it could incur additional damage if
used.  Use extreme caution.
</text></DescriptionText>
</ServiceInformation>
<Cause>
The machine checks vacuum on the drum after the media is loaded.  This error
occurs because the drum vacuum level is too low.  This is probably
due to the media being loaded incorrectly.  It is also possible
that the drum vacuum sensor is not working properly, the thresholds
are not set properly, or vacuum is not being generated properly.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/proof.xml</LinkAddress><LinkTitle>Command: proof</LinkTitle></Link>
<Link><LinkAddress>../commands/pload.xml</LinkAddress><LinkTitle>Command: pload</LinkTitle></Link>
<Link><LinkAddress>../commands/punload.xml</LinkAddress><LinkTitle>Command: punload</LinkTitle></Link>
<Link><LinkAddress>../nvs/alproof_cfg_vsi.xml</LinkAddress><LinkTitle>NVS: alproof vsi</LinkTitle></Link>
<Link><LinkAddress>../nvs/alproof_cal_rvgt.xml</LinkAddress><LinkTitle>NVS: alproof rvgt</LinkTitle></Link>
<Link><LinkAddress>../nvs/proof_cal_dvct.xml</LinkAddress><LinkTitle>NVS: proof dvct</LinkTitle></Link>
<Link><LinkAddress>../nvs/proof_cal_dvrt.xml</LinkAddress><LinkTitle>NVS: proof dvrt</LinkTitle></Link>
<Link><LinkAddress>../nvs/proof_cal_dvdt.xml</LinkAddress><LinkTitle>NVS: proof dvdt</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:05 2008 PST
</Updated>
<Links>
</Links>
</Error>